Blank worksheets appendix a – Rockwell Automation 1771-QDC, D17716.5.87(Passport) CLAMP AND EJECT MODE User Manual

Page 213

Advertising
background image

Enter Your Values Here

Blank Worksheets

Appendix A

A-13

Worksheet 7-C

(continued)

Third Clamp Close (TCC) Configuration Block

Control Word ProĆSet 600 Addr. Value

Description

Units

TCC05

N43:121

Minimum ERC

PercentageĆĆVelocity

Percent

8

TCC06

N43:122

Minimum ERC

PercentageĆĆPressure

Percent

8

TCC08

N43:124

Profile Watchdog Timer Preset

Time

1

TCC09

N43:125

Output #1 SetĆOutput Value during Profile

Percent Signal Output

4

TCC10

N43:126

Output #2 SetĆOutput Value during Profile

Percent Signal Output

4

TCC11

N43:127

Output #3 SetĆOutput Value during Profile

Percent Signal Output

4

TCC12

N43:128

Output #4 SetĆOutput Value during Profile

Percent Signal Output

4

TCC17

N43:133

Output #1 Acceleration Ramp Rate during Profile

Percent Signal Output per Second

5

TCC18

N43:134

Output #2 Acceleration Ramp Rate during Profile

Percent Signal Output per Second

5

TCC19

N43:135

Output #3 Acceleration Ramp Rate during Profile

Percent Signal Output per Second

5

TCC20

N43:136

Output #4 Acceleration Ramp Rate during Profile

Percent Signal Output per Second

5

TCC25

N43:141

Output #1 Deceleration Ramp Rate during Profile

Percent Signal Output per Second

5

TCC26

N43:142

Output #2 Deceleration Ramp Rate during Profile

Percent Signal Output per Second

5

TCC27

N43:143

Output #3 Deceleration Ramp Rate during Profile

Percent Signal Output per Second

5

TCC28

N43:144

Output #4 Deceleration Ramp Rate during Profile

Percent Signal Output per Second

5

TCC33

N43:149

Output #1 SetĆOutput Value at EndĆofĆProfile

Percent Signal Output

4

TCC34

N43:150

Output #2 SetĆOutput Value at EndĆofĆProfile

Percent Signal Output

4

TCC35

N43:151

Output #3 SetĆOutput Value at EndĆofĆProfile

Percent Signal Output

4

TCC36

N43:152

Output #4 SetĆOutput Value at EndĆofĆProfile

Percent Signal Output

4

TCC41

N43:157

Pressure Minimum Control Limit

Pressure

3

TCC42

N43:158

Pressure Maximum Control Limit

Pressure

3

TCC43

N43:159

Selected Pressure Valve Output for Minimum

Percent Signal Output

4

TCC44

N43:160

Selected Pressure Valve Output for Maximum

Percent Signal Output

4

TCC45

N43:161

Velocity Minimum Control Limit

Velocity along Axis

2

TCC46

N43:162

Velocity Maximum Control Limit

Velocity along Axis

2

TCC47

N43:163

Selected Velocity Valve Output for Minimum

Percent Signal Output

4

TCC48

N43:164

Selected Velocity Valve Output for Maximum

Percent Signal Output

4

TCC49

N43:165

Proportional Gain for Pressure Control

None

TCC50

N43:166

Integral Gain for Pressure Control

Inverse Time (Algorithm)

6

TCC51

N43:167

Derivative Gain for Pressure Control

Time (Algorithm)

7

Time

1

TCC52

N43:168

Proportional Gain for Velocity Control

Inverse Time (Algorithm)

6

TCC53

N43:169

Feed Forward Gain for Velocity Control

None

TCC57

N43:173

Profile High Pressure Alarm Setpoint

Pressure

3

1

Time

2

Velocity along Axis

3

Pressure

4

Percent Signal Output

00.00 to 99.99 Seconds 00.00 to 99.99 Inches per Second 0000 to 9999 PSI 00.00 to 99.99

000.0 to 999.9 Millimeters per Sec 000.0 to 999.9 Bar

5

Percent Signal Output per Second

6

Inverse Time (Algorithm)

7

Time (Algorithm)

8

Percent

0000 to 9999 00.00 to 99.99 Minutes 00.00 to 99.99 Minutes 00.00 to 99.99

00.00 to 99.99 Seconds

Advertising