Enter and download your worksheet values, 8ć13 – Rockwell Automation 1771-QDC, D17716.5.87(Passport) CLAMP AND EJECT MODE User Manual

Page 127

Advertising
background image

Load Initial Profile Values for

Machine Tuning

Chapter 8

8-13

Velocity Setpoints (OPC09, OPC12, OPC15, OPC18, OPC21, OPC24,
OPC27, OPC30, OPC33, OPC36, OPC39)
Use these words when configuring Velocity vs. Position profiles. Each
velocity is used between the last completed clamp segment, and the End-of
Segment position setpoint.

Enter 0 for each Velocity Setpoint Value. The valve spanning procedures
presented in chapter 9 require these initial values. A detailed discussion of
these setpoints is presented in chapter 10 to assist you in selecting the
correct, final values required by your application. Refer to Section 3 of the
Plastic Molding Module Reference Manual (pub. no. 1771-6.5.88) for
more information.

Pressure Setpoints (OPC10, OPC13, OPC16, OPC19, OPC22, OPC25,
OPC28, OPC31, OPC34, OPC36, OPC40)
Use these words when configuring Pressure vs. Position profiles. Enter
pressure in PSI or Bar. Each pressure is used to control the axis between the
last completed clamp segment, and the End-of Segment position setpoint.

Enter 0 for each Pressure Setpoint Value. The valve spanning procedures
presented in chapter 9 require these initial values. A detailed discussion of
these setpoints is presented in chapter 10 to assist you in selecting the
correct, final values required by your application. Refer to Section 3 of the
Plastic Molding Module Reference Manual (pub. no. 1771-6.5.88) for more
information.

Mold Open Dwell Timer Preset (OPC63)
The QDC module starts an internal Mold Open Dwell Timer dependent on
the state of OPC03-B15.

Enter 0 for the Mold Open Dwell Timer Preset. For additional information
in selecting the correct, final value required by your application, refer to
Section 3 of the Plastic Molding Module Reference Manual (pub. no.
1771-6.5.88).

Enter completed Worksheet 8-B values into your PLC data table using the
procedure discussed in chapter 4. Download the values to the QDC
module.

Check SYS61 and SYS62 for programming errors, and correct as
necessary. Make sure no programming errors exist before proceeding.