Enter Your Values Here

Blank Worksheets

Appendix A

A-27

Worksheet 7-J

(continued)

Ejector Retract (ERC) Configuration Block

Control Word ProĆSet 600 Addr. Value

Description

Units

ERC05

N45:61

Minimum ERC

PercentageĆĆVelocity

Percent

8

ERC06

N45:62

Minimum ERC

PercentageĆĆPressure

Percent

8

ERC09

N45:65

Output #1 SetĆOutput Value during Retract

Percent Signal Output

4

ERC10

N45:66

Output #2 SetĆOutput Value during Retract

Percent Signal Output

4

ERC11

N45:67

Output #3 SetĆOutput Value during Retract

Percent Signal Output

4

ERC12

N45:68

Output #4 SetĆOutput Value during Retract

Percent Signal Output

4

ERC17

N45:73

Output #1 Acceleration Ramp Rate during Retract

Percent Signal Output per Second

5

ERC18

N45:74

Output #2 Acceleration Ramp Rate during Retract

Percent Signal Output per Second

5

ERC19

N45:75

Output #3 Acceleration Ramp Rate during Retract

Percent Signal Output per Second

5

ERC20

N45:76

Output #4 Acceleration Ramp Rate during Retract

Percent Signal Output per Second

5

ERC25

N45:81

Output #1 Deceleration Ramp Rate during Retract

Percent Signal Output per Second

5

ERC26

N45:82

Output #2 Deceleration Ramp Rate during Retract

Percent Signal Output per Second

5

ERC27

N45:83

Output #3 Deceleration Ramp Rate during Retract

Percent Signal Output per Second

5

ERC28

N45:84

Output #4 Deceleration Ramp Rate during Retract

Percent Signal Output per Second

5

ERC33

N45:89

Output #1 SetĆOutput Value at EndĆofĆRetract

Percent Signal Output

4

ERC34

N45:90

Output #2 SetĆOutput Value at EndĆofĆRetract

Percent Signal Output

4

ERC35

N45:91

Output #3 SetĆOutput Value at EndĆofĆRetract

Percent Signal Output

4

ERC36

N45:92

Output #4 SetĆOutput Value at EndĆofĆRetract

Percent Signal Output

4

ERC41

N45:97

Pressure Minimum Control Limit

Pressure

3

ERC42

N45:98

Pressure Maximum Control Limit

Pressure

3

ERC43

N45:99

Selected Pressure Valve Output for Minimum

Percent Signal Output

4

ERC44

N45:100

Selected Pressure Valve Output for Maximum

Percent Signal Output

4

ERC45

N45:101

Velocity Minimum Control Limit

Velocity along Axis

2

ERC46

N45:102

Velocity Maximum Control Limit

Velocity along Axis

2

ERC47

N45:103

Selected Velocity Valve Output for Minimum

Percent Signal Output

4

ERC48

N45:104

Selected Velocity Valve Output for Maximum

Percent Signal Output

4

ERC49

N45:105

Proportional Gain for Pressure Control

None

ERC50

N45:106

Integral Gain for Pressure Control

Inverse Time (Algorithm)

6

ERC51

N45:107

Derivative Gain for Pressure Control

Time (Algorithm)

7

Time

1

ERC52

N45:108

Proportional Gain for Velocity Control

Inverse Time (Algorithm)

6

ERC53

N45:109

Feed Forward Gain for Velocity Control

None

1

Time

2

Velocity along Axis

3

Pressure

4

Percent Signal Output

00.00 to 99.99 Seconds 00.00 to 99.99 Inches per Second 0000 to 9999 PSI 00.00 to 99.99

000.0 to 999.9 Millimeters per Sec 000.0 to 999.9 Bar

5

Percent Signal Output per Second

6

Inverse Time (Algorithm)

7

Time (Algorithm)

8

Percent

0000 to 9999 00.00 to 99.99 Minutes 00.00 to 99.99 Minutes 00.00 to 99.99

00.00 to 99.99 Seconds