Load initial configuration values chapter 7 – Rockwell Automation 1771-QDC, D17716.5.87(Passport) CLAMP AND EJECT MODE User Manual

Page 87

Advertising
background image

Enter Your Values Here

Load Initial Configuration Values

Chapter 7

7-11

Worksheet 7ĆD (continued)
Clamp Low Pressure Close (LPC) Configuration Block

Control Word ProĆSet 600 Addr. Value

Description

Units

LPC06

N43:182

1000

Minimum ERC

PercentageĆĆPressure

Percent

7

LPC07

N43:183

0

Tonnage Watchdog Timer Preset

Time

1

LPC08

N43:184

0

Profile Watchdog Timer Preset

Time

1

LPC09

N43:185

*

Output #1 SetĆOutput Value during Profile

Percent Signal Output

3

LPC10

N43:186

*

Output #2 SetĆOutput Value during Profile

Percent Signal Output

3

LPC11

N43:187

*

Output #3 SetĆOutput Value during Profile

Percent Signal Output

3

LPC12

N43:188

*

Output #4 SetĆOutput Value during Profile

Percent Signal Output

3

LPC17

N43:193

0

Output #1 Acceleration Ramp Rate during Profile

Percent Signal Output per Second

4

LPC18

N43:194

0

Output #2 Acceleration Ramp Rate during Profile

Percent Signal Output per Second

4

LPC19

N43:195

0

Output #3 Acceleration Ramp Rate during Profile

Percent Signal Output per Second

4

LPC20

N43:196

0

Output #4 Acceleration Ramp Rate during Profile

Percent Signal Output per Second

4

LPC25

N43:201

0

Output #1 Deceleration Ramp Rate during Profile

Percent Signal Output per Second

4

LPC26

N43:202

0

Output #2 Deceleration Ramp Rate during Profile

Percent Signal Output per Second

4

LPC27

N43:203

0

Output #3 Deceleration Ramp Rate during Profile

Percent Signal Output per Second

4

LPC28

N43:204

0

Output #4 Deceleration Ramp Rate during Profile

Percent Signal Output per Second

4

LPC33

N43:209

*

Output #1 SetĆOutput Value at EndĆof Profile

Percent Signal Output

3

LPC34

N43:210

*

Output #2 SetĆOutput Value at EndĆof Profile

Percent Signal Output

3

LPC35

N43:211

*

Output #3 SetĆOutput Value at EndĆof Profile

Percent Signal Output

3

LPC36

N43:212

*

Output #4 SetĆOutput Value at EndĆof Profile

Percent Signal Output

3

LPC41

N43:217

0

Pressure Minimum Control Limit

Pressure

2

LPC42

N43:218

System Pressure

Pressure Maximum Control Limit

Pressure

2

LPC43

N43:219

*

Selected Pressure Valve Output for Minimum

Percent Signal Output

3

LPC44

N43:220

*

Selected Pressure Valve Output for Maximum

Percent Signal Output

3

LPC49

N43:225

100

Proportional Gain for Pressure Control

None

LPC50

N43:226

400

Integral Gain for Pressure Control

Inverse Time (Algorithm)

5

LPC51

N43:227

0

Derivative Gain for Pressure Control

Time (Algorithm)

6

Time

1

LPC57

N43:233

0

Profile High Pressure Alarm Setpoint

Pressure

2

1

Time

2

Pressure

3

Percent Signal Output

4

Percent Signal Output per Second

00.00 to 99.99 Seconds 0000 to 9999 PSI 00.00 to 99.99 0000 to 9999

000.0 to 999.9 Bar

5

Inverse Time (Algorithm)

6

Time (Algorithm)

7

Percent

00.00 to 99.99 Minutes 00.00 to 99.99 Minutes 00.00 to 99.99

00.00 to 99.99 Seconds

*Refer to the appropriate section later in this chapter for information on this parameter