Select Command and Status Bits

to Sequence Machine Operation

Chapter 6

6-9

Table

6.J

(continued)

Operation:

Function Enabled

(when = 1):

QDC Block

Addr.:

ProĆSet

Addr:

Configured

Protection from

ClampĆzone

Overrun

If a clamp close profile overruns the

mold protection zone:

0 = start LPĆclose profile

1 = stop and zero outputs

CPC03ĆB11

B37/299

If a clamp open profile overruns the

clamp open slow zone

0 = start open slow profile

1 = stop and zero outputs

OPC03ĆB11

B37/619

Additional Ejector

Configuration

start ejector profile on command from PLC

processor

(0 = start ejector profile on position during

clamp open profile)

EPC03ĆB08

B39/168

disable ejector profile

(0 = enable ejector profile)

EPC03ĆB09

B39/169

change intermediate strokes to tip strokes

(0 = all ejector strokes are full strokes)

EPC03ĆB13

B39/173

execute forward dwell after 1st advance stroke

(0 = execute forward dwell after last advance

stroke)

EPC03ĆB15

B39/175