System Commissioning

Chapter 6

Create Your FactoryTalk View Runtime Application File

Follow these steps to create a runtime file for downloading to a PanelView Plus terminal.

1.

From the Application menu, choose Create
Runtime Application.

The Create Runtime Application dialog box
opens.

2.

From the Save as type pull-down menu,
choose Runtime 5.10 Application (*.mer).

3.

Enter a File Name for the application.

For the Widg-O-matic application example,
the file name is WidgOmatic_HMI.mer.

4.

Click Save.

The Runtime application (*.mer) file is
created. This may take a few minutes.

Download Runtime File to PanelView Plus Terminal

1.

Open FactoryTalk View Studio Machine
Edition software.

2.

From the Tools menu, choose Transfer
Utility.

The Transfer Utility window opens.