Controller to device communication, Clearing faults, Hmi clear faults – Rockwell Automation 193 Drives and Motion Accelerator Toolkit Quick Start User Manual

Page 168

Advertising
background image

168

Rockwell Automation Publication IASIMP-QS019E-EN-P - August 2013

Chapter 6

System Commissioning

Controller to Device Communication

Verify controller to device communication by observing the indicators on the controller’s communication
module and the devices in the controller’s I/O tree.

Observe the controller’s communication module. Refer to the user manual
for the specific module you are using.

Ethernet Module Status Indicators

Open your Logix Designer project, go online with the controller, and observe
the devices in the I/O tree. A device with a yellow exclamation mark (!)
indicates a fault. The fault could be a configuration fault, a device fault, or a
communication fault. View the quick pane in the Controller Organizer to
determine fault.

Clearing Faults

After all of the devices are connected and functioning on the network, clear faults to put the machine in a
STOPPED state.

HMI Clear Faults

When the controller powers-up and the program goes into Run mode, the machine is faulted and in the
ABORTED state. Refer to

Appendix A

, on

page 203

, for more information on the logic program modules.

You can attempt to clear the machine faults by pressing the Clear Faults push button on the HMI terminal. If
there are no faults, the machine state goes to STOPPED. Refer to

Chapter 5

, on

page 101

, for more information

on the HMI application programming.

Status Indicator

Status

OK

Solid green

LNK1

Flashing green (indicates network activity)

LNK2

Off (flashing green if in a Device Level Ring configuration)

OK

LNK2

LNK1

1756-EN2TR
Ethernet Module