System Commissioning

Chapter 6

Test and Tune the Axis

Use the Logix Designer application to access Axis Properties and run the Hookup test and Tune test.

The Hookup test verifies encoder connections and direction.

The tuning values for position units, velocity gains, acceleration, and deceleration rates are set in Axis
Properties based on the drive/motor combination and motor inertia only. The Autotuning procedure
calculates the gain values dynamically after determining inertia.

For more information on test and tune procedures for sercos drives, refer to the appropriate user manual listed in

Additional Resources

on

page 15

.

Commissioning PowerFlex 7-class Drives

These commissioning procedures cover PowerFlex 70EC, PowerFlex 700, PowerFlex 753, and PowerFlex 755
drives.

For more information on drive commissioning, refer to the appropriate user manual listed in

Additional

Resources

on

page 15

.

Apply Power to the Drive

Apply control power first if using an auxiliary power supply option, and then apply three-phase drive power.

Status Indicators

Verify the drives are ready.

PowerFlex 755 Drive Status Indicators

PowerFlex 753 Drive Status Indicators

Status Indicator

Status

STS

Flashing green

ENET

Solid green

LINK

Flashing green (indicating network activity)

Status Indicator

Status

STS

Flashing green

STS

ENET

LINK

PowerFlex 755
Status Indicators

STS

PowerFlex 753
Status Indicators

Advertising