Candle KLVHSKONCT GC32-9172-00 User Manual

Page 104

Advertising
background image

104

Candle Products Messages Manual (KLVHS–KONCT)

KLVTB006

NO LSR POOL ALLOCATED

Explanation: CT/Engine tables initialization was unable to process the tables
database because no VSAM LSR environment was established.
System Action: CT/Engine initialization is terminated.
User Response: Examine the MVS console log or the CT/Engine RKLVLOG
for KLVVSnnn messages, which will explain the VSAM problem. Correct the error,
then restart CT/Engine.
Message Type:

ERROR.

KLVTB007

UNABLE TO ACCESS TABLE CLUSTER

Explanation: CT/Engine tables initialization was unable to process the tables
database because it could not establish a VSAM request against the cluster.
System Action: CT/Engine initialization is terminated.
User Response: Retain the CT/Engine run sheets and dump files, and the MVS
system log, then contact Candle Customer Support.
Message Type:

ERROR.

KLVTB008

UNABLE TO READ TABLE DATABASE CONTROL RECORD

Explanation: CT/Engine tables initialization could not read information it needs
to process the tables database.
System Action: CT/Engine initialization is terminated.
User Response: Retain the CT/Engine run sheets and dump files, and the MVS
system log, then contact Candle Customer Support.
Message Type:

ERROR.

KLVTB009

UNABLE TO WRITE TABLE DATABASE CONTROL RECORD

Explanation: CT/Engine tables initialization could not update the tables
database.
System Action: CT/Engine initialization is terminated.
User Response: Retain the CT/Engine run sheets and dump files, and the MVS
system log, then contact Candle Customer Support.
Message Type:

ERROR.

KLVTB010

SHOWCB FIELDS = (ACBLEN,RPLLEN) ERROR: R15(r15) R0(r0)

Explanation: CT/Engine tables initialization could not format the tables
database because the VSAM SHOWCB macro failed.
System Action: CT/Engine initialization is terminated.
User Response: Retain the CT/Engine run sheets and dump files, this message,
and the MVS system log, then contact Candle Customer Support.
Message Type:

ERROR.

KLVTB011

UNABLE TO INITIALIZE TABLE CLUSTER DSNAME(dsname) R15(value)
DCR(
hex)

Explanation: CT/Engine tables initialization could not format the tables
database because the VSAM OPEN macro failed.
System Action: CT/Engine initialization is terminated.
User Response: Retain the CT/Engine run sheets and dump files, this message,
and the MVS system log, then contact Candle Customer Support.
Message Type:

ERROR.

Advertising