Candle KLVHSKONCT GC32-9172-00 User Manual

Page 73

Advertising
background image

KLVHS001–KLVSC009

73

KLVRM004

LOGICAL RESOURCE EXIT STACK INTEGRITY ERROR

Explanation: The CT/Engine Resource Manager detected inconsistent data
while processing a logical resource purge or cleanup request, usually because of a
storage overlay.
System Action: The request is terminated with a U0100 abend, sending a
dump to the RKLVSNAP file and/or the system’s dump data sets. The resource
involved is left in an indeterminate state.
User Response: Recycle the CT/Engine address space as soon as possible.
Retain the CT/Engine run sheets, dump files, this message, and the MVS system
log, then contact Candle Customer Support.
Message Type:

ABEND.

KLVRS001

INVALID $RSS REQUEST

Explanation: KLV$RSS detected an invalid function code in its input parameter
list.
System Action: The thread is terminated.
User Response: Contact Candle Customer Support. Keep dump, RKLVLOG,
SYSLOG, and runsheets.
Message Type:

ABEND.

KLVRS002

INVALID RSS RELEASE REQUEST

Explanation: An RSS release request was made for a lock that was not held.
System Action: The thread is terminated.
User Response: Contact Candle Customer Support. Keep dump, RKLVLOG,
SYSLOG, and runsheets.
Message Type:

ABEND.

KLVRT001

PARAMETER ERROR

Explanation: CT/Engine detected an invalid RTM event code.
System Action: A call to RTM fails. CT/Engine creates a DUMP and continues
processing.
User Response: Contact Candle Customer Support with the contents of the
DUMP.
Message Type:

ABEND.

KLVRT010

RTM NPM INTERFACE event IS UNRECOGNIZED

Explanation: The NPM interface module does not recognize the session
manager event code passed. Event code is a 2 hexadecimal digit field.
System Action: The NSI vector containing the session manager event is not
processed.
User Response: Contact Candle Customer Support.
Message Type:

INFO.

Advertising