KMQxx001E–KOCJ0046

287

KMQTR103E

BAD RETURN CODE FROM NAME/TOKEN SERVICES

Explanation: CCC for MQSeries received a bad return code while attempting to
use the MVS/ESA name or token services.
System Action: Processing continues but component tracing may not
function.
User Response: Investigate whether MVS/ESA modules IEANTRT, IEANTCR,
and IEANTDL are globally available to the MVS/ESA system. If the problem
persists after they have been made available as common service routines, contact
Candle Customer Support.

KMQTR104I

TRACE COMP=KMQ100 BUFFER SIZE SET TO nnnnnnnnK.

Explanation: The internal component trace table size was set to the value of
nnnnnnnn

kilobytes.

System Action: nnnnnnnnK of virtual storage will be used for each internal
trace buffer. When tracing is active, there are at least 18 separate trace buffers in
each CCC for MQSeries address space.
User Response: None. This is an informational message only.

KMQTR105E

INVALID SUBNAME SPECIFIED. name

Explanation: A TRACE CT operator command was issued with the named
sub-trace. The named sub-trace was not initialized or the name is invalid.
System Action: None.
User Response: Specify another sub-trace name, or omit the sub-trace name
which sets tracing for all sub-traces.

KMQTR106E

INVALID ASID SPECIFIED. Xparameter

Explanation: A TRACE CT operator command was issued with the indicated
hex ASID parameter. The ASID is invalid or not available.
System Action: None.
User Response: Specify a valid hex ASID parameter on the TRACE CT
operator command.

KMQTR107E

INVALID JOBNAME SPECIFIED. parameter

Explanation: A TRACE CT operator command was issued with the indicated
JOBNAME parameter. The JOBNAME is invalid or not available.
System Action: None.
User Response: Specify a valid JOBNAME parameter on the TRACE CT
operator command.

KMQTR111I

TRACE STARTED FOR COMP=component SUB=sub

Explanation: Application component tracing has started in the system for the
named component and sub-trace component. Tracing can be stopped or
modified by operator commands. For more information about controlling
component traces, refer to the MVS/ESA SP System Commands.
System Action: The system trace continues until it is stopped by the TRACE
CT operator command.
User Response: None. This is an informational message only.