Candle Products Messages Manual (KLVHS–KONCT)

KLVOP302

VIEWLOG CLUSTER NOT AVAILABLE

Explanation: The VIEWLOG cluster specified in the VIEWLOG command is not
available.
System Action: The command fails.
User Response: Look for other messages, KLVVL002 or KLVVL008, to
determine a more specific reason why the cluster is not available, and take
corrective action.
Message Type:

ERROR.

KLVOP303

VIEWLOG CLUSTER NOT ACCESSIBLE

Explanation: The VIEWLOG cluster specified in the VIEWLOG command
could not be accessed.
System Action: The command fails.
User Response: Examine the log for other error messages concerning the
VIEWLOG cluster and take corrective action.
Message Type:

ERROR.

KLVOP304

DATE FIELD INVALID: DATE(date)

Explanation: The date field date specified in the VIEWLOG FDATE command
is invalid.
System Action: The command fails.
User Response: Specify the date as mm/dd/yy.
Message Type:

ERROR.

KLVOP312

AS COMMAND MAY NOT BE DIRECTED TO operator

Explanation: The AS command cannot be directed to operator operator.
System Action: The command fails.
User Response: Validate the operator parameter and reissue the command.
Message Type:

ERROR.

KLVOP314

COMMAND ISSUED

Explanation: The AS command was issued.
System Action: None.
User Response: None.
Message Type:

REPLY.

KLVOP315

OPERATOR operator NOT LOGGED ON

Explanation: The AS command was issued but the operator operator was not
logged on.
System Action: The command fails.
User Response: If operator is *SYSVLG* check RKLVLOG for messages to
determine why *SYSVLG* was logged off. The VIEWLOG dataset may be full.
For all other operators, verify that you are using the correct ID and reissue the
command.
Message Type:

ERROR.