Candle Products Messages Manual (KLVHS–KONCT)

System Action: NCP statistics information is not available.
User Response: Log the information displayed for problem diagnosis and
contact Candle Support Services.
Message Type:

Internal error.

KN3AF006

MEMBER KN3CNMAP CONTAINS INVALID ACB NAME

Explanation: The ACB name found exceeds eight alphanumeric characters.
System Action: None.
User Response: Correct the ACB name and restart OMEGAMON II for VTAM.
Message Type:

User error.

KN3AF007

MEMBER KN3CNMAP IS EMPTY OR NOT FOUND

Explanation: The member KN3CNMAP does not exist in dataset RKANPAR, or
this member does not contain the ACB name to be used for the communication
network management (CNM) interface.
System Action: None.
User Response: Check the OMEGAMON II for VTAM Configuration and
Customization Guide

about member KN3CNMAP, which resides in dataset

RKANPAR.
Message Type:

User error.

KN3AF010

CRB ALLOCATION FAILED DURING [TRACE CLEANUP] | [TRACE
DELETE] | [TRACE DISPLAY] | [TRACE INSTALL] | [TRACE REMOVAL] |
[TRACE START] | [TRACE STATUS] | [TRACE STOP] [VTAM TABLE
DISPLAY] — MODULE(
error_module) RC(return_code)

Explanation: Collector Request Block (CRB) allocation failed while processing
the specified function.
System Action: The request was not processed.
User Response: Gather the preceding 30 minutes of the RKLVLOG and any
dumps that were produced or taken, and contact Candle Support Services.
Message Type:

Internal error.

KN3AF011

CRB FREE FAILED DURING [TRACE DELETE] | [TRACE DISPLAY] |
[TRACE INSTALL] | [TRACE REMOVAL] | [TRACE START] | [TRACE
STATUS] | [TRACE STOP] [VTAM TABLE DISPLAY] —
MODULE(
error_module) RC(return_code)

Explanation: An attempt to free the Collector Request Block (CRB) failed upon
completion of the specified function.
System Action: The request was processed, but the Collector Request Block
was not freed.
User Response: While this problem does not immediately affect you, repeated
occurrences indicate an internal error. If problem persists, gather the preceding 30
minutes of the RKLVLOG and any dumps that were produced or taken, and
contact Candle Support Services.
Message Type:

Internal error.

Advertising