Candle Products Messages Manual (KLVHS–KONCT)

KLVST007

BLDVRP FAILED FOR VSAM LSR BUFFER POOL, RC=rc

Explanation: A BLDVRP macro was issued to allocate a VSAM local shared
resource buffer pool and ended with a non-zero return code, rc. The two most
likely causes are:
1. Insufficient main storage to satisfy the request.

2. A previously issued BLDVRP was issued without a corresponding DLVRP in

the CT/Engine address space. This typically occurs when CT/Engine is
running in a TSO address space and has previously abended in the current
TSO session.

System Action: CT/Engine terminates.
User Response: Refer to the IBM VSAM or DFP manual that describes the
BLDVRP macro for the meaning of rc. For the two most likely causes:
1. Adjust the main storage allocation parameters and/or LSRPOOL values and

restart the CT/Engine address space.

2. Start CT/Engine in a fresh address space.

Message Type:

ALERT.

KLVST008

PRIMARY MAIN STORAGE UNAVAILABLE

Explanation: A variable length GETMAIN could not be satisfied. The
MINIMUM(nnn,P) start-up parameter regulates the minimum value that will
satisfy the GETMAIN request. This refers to below the line storage.
System Action: CT/Engine terminates.
User Response: Adjust the MINIMUM parameter and retry.
Message Type:

ALERT.

KLVST009

FREEMAIN TYPE=VC FAILED

Explanation: A FREEMAIN that was issued for a previously allocated block of
main storage has failed.
System Action: CT/Engine terminates.
User Response: Contact Candle Customer Support.
Message Type:

ALERT.

KLVST010

PRIMARY RESERVED MAIN STORAGE UNAVAILABLE

Explanation: Insufficient main storage exists to satisfy the requirements for the
start-up parameter RESERVE(nnn,P). This message refers to below the line
storage.
System Action: CT/Engine terminates.
User Response: Adjust the storage allocation parameters, and retry.
Message Type:

ALERT.

KLVST011

PRIMARY STORAGE NOT REALLOCATED

Explanation: A GETMAIN macro instruction failed.
System Action: CT/Engine terminates.
User Response: Retry the start-up procedure.
Message Type:

ALERT.

Advertising