Candle KLVHSKONCT GC32-9172-00 User Manual

Page 23

Advertising
background image

KLVHS001–KLVSC009

23

KLVNA017

DATABASE KEY LENGTH NOT n: DSNAME(dsname) CNTRLPT(cntrlpt)

Explanation: While processing the NAM database dsname for control point
cntrlpt

, an error was detected in the key length. The length must be equal to n.

Either an incorrect version of the NAM database is being used, or the database
was not defined properly.
System Action: CT/Engine start-up terminates.
User Response: Delete the NAM database in error, redefine it, and restart
CT/Engine. You may need to refer to the original installation procedures to
determine the correct parameters when defining the NAM database.
Message Type:

WARNING.

KLVNA018

DATABASE CONTROL RECORD NOT FOUND: DSNAME(dsname)
CNTRLPT(
cntrlpt)

Explanation: While attempting to initialize the NAM environment for control
point cntrlpt, an error was detected in the VSAM dataset dsname. The control
record for the database could not be located. This message is accompanied by
KLVVSnnn messages, that give a more specific reason for failure to locate the
record.
System Action: CT/Engine start-up terminates.
User Response: Look in the log for other messages concerning this dataset to
determine a more specific reason for the error. If none can be found, contact
Candle Customer Support.
Message Type:

WARNING.

KLVNA019

DATABASE INITIAL LOAD FAILED: DSNAME(dsname) CNTRLPT(cntrlpt)
R15(
r15) RPLERRCD(rplerrcd)

Explanation: An I/O error was detected while processing the NAM cluster.
System Action: CT/Engine start-up fails.
User Response: Consult the IBM manual Macro Instructions for Data Sets to
determine the reason the PUT macro instruction failed. Return and error codes
are indicated in the r15 and rplerrcd fields. If the error cannot be attributed to a
user error, contact Candle Customer Support.
Message Type:

WARNING.

KLVNA020

keyword(value) IS INVALID FOR CNTRLPT(cntrlpt); DEFAULTS TO def

Explanation: keyword in the KLVINNAM member of RKANPAR was specified
with a value that is not a valid choice.
System Action: The default value, def, will be used. CT/Engine initialization
continues.
User Response: Correct the keyword value. If the default value is
unacceptable, recycle CT/Engine.
Message Type:

WARNING.