KM2EXPFF–KMCRCA002I

203

KMC0288E

Invalid disconnect interval

@2

.

Explanation: You specified an invalid disconnect interval for the channel.
User Response: Specify a valid disconnect interval. The value must be greater
than or equal to zero, and less than or equal to 999,999.

KMC0289E

Invalid maximum priority

@2

.

Explanation: You specified an invalid maximum priority value for the Queue
Manager.
User Response: Specify a valid maximum priority value. Specify a value in the
range 0 through 9.

KMC0290E

Invalid heartbeat interval

@2

.

Explanation: You specified an invalid heartbeat interval for the channel.
User Response: Specify a valid heartbeat interval. The value must be greater
than or equal to zero, and less than or equal to 999,999.

KMC0291E

Invalid batch interval

@2

.

Explanation: You specified an invalid batch interval for the channel.
User Response: Specify a valid batch interval. The value must be greater than
or equal to zero, and less than or equal to 999,999,999.

KMC0292E

Invalid max handles value

@2

.

Explanation: You specified an invalid maximum open handles value for the
Queue Manager.
User Response: Specify a valid maximum open handles value. Do not specify
a value less than zero or greater than 999,999,999.

KMC0293E

Invalid trigger interval

@2

.

Explanation: You specified an invalid trigger interval for the Queue Manager.
User Response: Specify a valid trigger interval. Do not specify a value less than
zero or greater than 999,999,999.

KMC0294E

Invalid service interval

@2

.

Explanation: You specified an invalid service interval for the queue.
User Response: Specify a valid service interval. The value is in units of
milliseconds, and must be greater than or equal to zero, and less than or equal to
999,999,999.

KMC0295E

Invalid retention interval

@2

.

Explanation: You specified an invalid retention interval for the queue.
User Response: Specify a valid retention interval. The value must be greater
than or equal to zero, and less than or equal to 999,999,999.

KMC0296E

Invalid trigger depth

@2

.

Explanation: You specified an invalid trigger depth for the queue.
User Response: Specify a valid trigger depth. The value must be greater than
zero, and less than or equal to 999,999,999.