307

KMVCCC150E

Error processing predicate: pdt

Explanation: An error occurred processing the situation predicate.
System Action: The user is prevented from editing the situation.
User Response: Use the Candle Management Workstation editor to determine
the nature of the error.
Message Type:

Error.

KN3000000E

ERROR RESOLVING NODENAME nnn

Explanation: None name nnn could not be resolved.
System Action: Processing continues.
User Response: If problem persists, contact Candle Support Services.

KN3AF001

OMEGAMON II for VTAM SHUTDOWN INITIATED –VTAM IS NOT ACTIVE

Explanation: OMEGAMON II for VTAM detected that VTAM was inactive and
initiated shutdown.
System Action: None.
User Response: Investigate the reason for the VTAM outage.
Message Type:

Warning.

KN3AF002

COLLECTOR ERROR DURING SAMPLING OR RECORDING INTERVAL
PROCESSING — MODULE(
error_module)

Explanation: A collector called during sample or recording interval processing
abended. Diagnostics data are written to the ONSNAP dump dataset and to the
program check or snap table in the product work area extension.
System Action: OMEGAMON II for VTAM continues to run if possible.
User Response: Gather the preceding 30 minutes of the RKLVLOG and any
dumps that were produced or taken, and contact Candle Support Services.
Message Type:

Internal error.

KN3AF003

BACKGROUND ETE COLLECTOR TERMINATED WITH ERROR —
MODULE(
error_module) RC(return_code) SC(sense_code)

Explanation: The background ETE collector terminated due to an internal error.
System Action: OMEGAMON II for VTAM continues to run without the ETE
background collector.
User Response: Gather the preceding 30 minutes of the RKLVLOG and any
dumps that were produced or taken, and contact Candle Support Services.
Message Type:

Internal error.

KN3AF004

ACT TERMINATED ABNORMALLY

Explanation: The automatic collection task (ACT) terminated abnormally.
System Action: The automatic collection task is unavailable.
User Response: Log the information displayed for problem diagnosis and
contact Candle Support Services.
Message Type:

Internal error.

KN3AF005

NDM FUNCTIONS MODULE KN3AFNDM LOAD FAILED. NCP
STATISTICS DATA NOT AVAILABLE

Explanation: The automatic collection task (ACT) load of the NCP data
manager (NDM) functions module failed.

Advertising