Candle KLVHSKONCT GC32-9172-00 User Manual

Page 35

Advertising
background image

KLVHS001–KLVSC009

35

KLVOP005

APPLICATION NOT ACCEPTING COMMANDS [text]

Explanation: A command was issued and directed to a CT/Engine application
that does not have a common interface. The optional text may be added by
CT/Engine modules to further describe the error.
System Action: The command terminates.
User Response: Validate the application applid to determine if a command
interface is defined. Reissue the command specifying a valid application name.
Message Type:

ERROR.

KLVOP006

COMMAND NOT FOUND [text]

Explanation: The command or CLIST issued could not be located. The optional
text

may be added by CT/Engine modules to further describe the error.

System Action: The command fails.
User Response: Verify that:
1. The command issued is a valid CT/Engine command, or

2. The CLIST is located in the CT/Engine command library (RKANCMD).

Message Type:

ERROR.

KLVOP007

COMMAND NOT AUTHORIZED [text]

Explanation: A CT/Engine command issued by an unauthorized operator. The
optional text may be added by CT/Engine modules to further describe the error.
System Action: The command fails.
User Response: None.
Message Type:

ERROR.

KLVOP008

clist CLIST COMPLETED

Explanation: The RKANCMD clist member clist has completed execution.
System Action: None.
User Response: None.
Message Type:

REPLY

KLVOP009

command COMMAND COMPLETED

Explanation: The command command has completed its output.
System Action: None.
User Response: None.
Message Type:

REPLY

KLVOP011

INVALID CLASS NAME: class

Explanation: The DISPLAY command was issued with an invalid class class.
System Action: The command fails.
User Response: Re-enter the command with a valid class.
Message Type:

ERROR.