Candle Products Messages Manual (KLVHS–KONCT)

KN3AF041

ETE CONNECTION FAILED — MODULE(error_module) RC(return_code)
SC(
sense_code)

Explanation: During session establishment for a user, OMEGAMON II for
VTAM detected that the end-to-end response time environment was not
connected. OMEGAMON II for VTAM encountered an error while attempting to
connect the ETE environment.
System Action: Session establishment continues without the ETE feature.
User Response: Verify that the ETE started task is active and that you are
running the correct level of ETE. Also, review the information on enabling ETE in
the OMEGAMON II for VTAM Configuration and Customization Guide. Verify
that all steps completed are accurate. Then, retry logon. If problem persists, gather
the preceding 30 minutes of the RKLVLOG and any dumps that were produced
or taken, and contact Candle Support Services.
Message Type:

Probable user error.

KN3AF042

UNABLE TO FREEMAIN USERWORK DURING SESSION TERMINATION
— MODULE(
error_module) RC(return_code)

Explanation: FREEMAIN of a user work area failed during session termination.
(return_code is the FREEMAIN return code).
System Action: OMEGAMON II for VTAM continues operation.
User Response: Recurrence of this problem, while not detrimental to the
operation of OMEGAMON II for VTAM, indicates an internal error that needs to
be diagnosed by Candle Support Services. If problem persists, gather the
preceding 30 minutes of the RKLVLOG and any dumps that were produced or
taken, and contact Candle Support Services.
Message Type:

Internal error.

KN3AF043

TRACE CLEANUP DETECTED AN ABEND CONDITION — ADDITIONAL
CLEANUP STARTED — MODULE(
error_module)

Explanation: A trace facility abend condition was detected while in the process
of removing outstanding traces for a terminating user.
System Action: Trace cleanup attempts to continue.
User Response: If problem persists, gather the preceding 30 minutes of the
RKLVLOG and any dumps that were produced or taken, and contact Candle
Support Services.
Message Type:

Internal error.

KN3AF044

ERROR ENCOUNTERED DURING TRACE CLEANUP —
MODULE(
error_module) RC(return_code) SC(sense_code)
USERWORK(
userwork_address) TRACE
HEADER(
trace_header_block_address)

Explanation: OMEGAMON II for VTAM was unable to remove an outstanding
VTAM trace for a terminating user.
System Action: Trace cleanup continues to remove remaining outstanding
traces for the terminating user.
User Response: If problem persists, gather the preceding 30 minutes of the
RKLVLOG and any dumps that were produced or taken, and contact Candle
Support Services.