Candle KLVHSKONCT GC32-9172-00 User Manual

Page 323

Advertising
background image

KMQxx001E–KOCJ0046

323

KN3AF148

module_name LOWER LEVEL MONITORED RESOURCES EXIST FOR
resource_name

Explanation: A request to stop monitoring an NCP resource has been entered,
but there are lower level resources which are still being monitored. These
resources must be manually stopped, before the requested resource can be
stopped module_name is the name of the module detecting the error, and
resource_name

is the name of the resource that was to be stopped.

System Action: A pop-up appears explaining the available options.
User Response: None.
Message Type:

Warning.

KN3AF149

module_name GET CRB FAILED, RC=return_code, SC=sense_code

Explanation: Module(module_name) was unable to obtain a Collector Request
Block (CRB). return_code is the return code and sense_code is the sense code
from the KN3AXCRB macro.
System Action: No data is displayed for some fields.
User Response: Log the information displayed for problem diagnosis and
contact Candle Support Services.
Message Type:

Internal error.

KN3AF150

module_name COLLECTOR(collector_module) ERROR, RC=return_code,
SC=
sense_code

Explanation: Module(module_name) called collector module
(collector_module) to obtain data. The collector was unable to obtain the
requested data.return_code is the return code and sense_code is the sense code
from the collector.
System Action: No data is displayed for some fields.
User Response: Log the information displayed for problem diagnosis and
contact Candle Support Services.
Message Type:

Internal error.

KN3AF151

SMF RESPONSE TIME RECORDING FOR NCP RESOURCES IS INACTIVE

Explanation: The automatic collection task (ACT) cannot collect response time
data for NCP resources because of any of the following reasons:

®

The NPALU is inactive.

®

The NCP collector is down.

®

The NCP collector is not connected to the NPALU.

System Action: SMF response time groups for NCP resources are marked
inactive in OMEGAMON II for VTAM and no SMF records are written for these
groups.
User Response: Investigate the status of the NPALU, NCP collector, and the
session between them. Refer to the OMEGAMON II for VTAM Configuration and
Customization Guide

.

Message Type:

Warning.

Advertising