KOGCM001–KONCT303

485

KOGVS05E

VU SERVER IPC QUEUE CREATE ERROR=

status

Explanation: An attempt to create the interprocess communication queue for
the VU Server process has failed. The status value indicates the return code
received from the IPC service routine called to create the message queue. This
message is issued when the CT/DS address space is not properly configured or
installed.
System Action: VU Server startup is aborted.
User Response: Review installation and configuration of the CT/DS software. If
the problem source cannot be determined, call Candle Customer Support.

KOGVS06E

UNABLE TO START PLU APPLID=

applid

STATUS=

status

Explanation: The VTAM Primary Logical Unit Application ID specified in the
KDSCNFG member of the TLVPARM ddname dataset cannot be opened by the
VU Server. The applid value indicates the value specified on the START
KOGVUSRV control statement. This value is required and must specify an active
VTAM APPLID defined for the VU Server process.
System Action: VU Server is aborted.
User Response: Correct the START KOGVUSRV startup control statement to
refer to a valid PLU APPLID as described in the installation documentation. Verify
that the PLU APPLID is properly configured and varied active.

KOGVS10E

IPC DEQUEUE ERROR=

status

Explanation: An attempt to read data from the interprocess communication
queue for the VU Server process has failed. The status value indicates the return
code received from the IPC service routine called to read the message queue. This
message is issued when the CT/DS address space is not properly configured or
installed.
System Action: VU Server execution is terminated.
User Response: Review installation and configuration of the CT/DS software. If
the problem source cannot be determined, call Candle Customer Support.

KOGVS11I

VU SERVER SHUTDOWN IN PROGRESS

Explanation: This message is issued during the shutdown of the CT/DS address
space to indicate that VU Server shutdown has begun.
System Action: VU Server continues cleanup and termination processing.
User Response: None. This is an informational message.

KOGVS12E

INVALID IPC MESSAGE RECEIVED. LENGTH=

length

Explanation: An incorrectly formatted message was received from the VU
Server interprocess communication message queue. The length value indicates
the length of the improperly formatted message. This message is issued when the
VU Server software is not properly configured or installed.
System Action: VU Server execution is terminated.
User Response: Review installation and configuration of the VU Server
software. If the problem source cannot be determined, call Candle Customer
Support.