Timer 2 Control (T2CON)

R = Unrestricted read, W = Unrestricted write, -n = Value after reset

7

6

5

4

3

2

1

0

SFR C8h

TF2

EXF2

RCLK

TCLK

EXEN2

TR2

C/T2

CP/RL2

RW-0

RW-0

RW-0

RW-0

RW-0

RW-0

RW-0

RW-0

TF2
Bit 7

EXF2
Bit 6

RCLK
Bit 5

TCLK
Bit 4

EXEN2
Bit 3

TR2
Bit 2

C/

T2

Bit 1

CP/

RL2

Bit 0

Timer 2 overflow flag. This bit is set when timer 2 overflows from FFFFh or the count is equal to the cap-
ture register in down-count mode. It must be cleared by software. This bit can only be set if RCLK and

TCLK are both cleared to 0.

Timer 2 external flag. A negative transition on the T2EX (P1.1) causes this flag to be set if (CP/PL2 =
EXEN2 = 1) or (CP/PL2 = DCEN = 0 and EXEN2 = 1). When CP/PL2 = 0 and DCEN = 1, this bit toggles

whenever timer 2 underflows or overflows. In this mode, EXF2 can be used as the 17th timer bit and

does not cause an interrupt. If set by a negative transition, this flag must be cleared by software. Setting

this bit forces a timer interrupt, if enabled.

Receive clock flag. This bit determines the serial port 0 time base when receiving data in serial modes
1 or 3. Setting this bit to 1 causes timer 2 overflow to be used to determine receive baud rate and forces

timer 2 into baud-rate generation mode, which operates from divide-by-2 of the external clock. Clearing

this bit to 0 causes timer 1 overflow to be used.

Transmit clock flag. This bit determines the serial port 0 time base when transmitting data in serial
modes 1 or 3. Setting this bit to 1 causes timer 2 overflow to be used to determine transmit baud rate

and forces timer 2 into baud-rate generation mode, which operates from divide-by-2 of the external

clock. Clearing this bit to 0 causes timer 1 overflow to be used.

Timer 2 external enable. Setting this bit to 1 enables the capture/reload function on the T2EX (P1.1) pin
for a negative transition, if timer 2 is not generating baud rates for the serial port. Clearing this bit to 0

causes timer 2 to ignore all external events on T2EX pin.

Timer 2 run control. This bit enables timer 2 operation when set to 1. Clearing this bit to 0 halts timer
2 operation and preserves the current count in TH2 and TL2.

Counter/timer select. This bit determines whether timer 2 functions as a timer or counter. Setting this
bit to 1 causes timer 2 to count negative transitions on the T2 (P1.0) pin. Clearing this bit to 0 causes

timer 2 to function as a timer. The speed of timer 2 is determined by the T2M (CKCON.5) bit. Timer 2

operates from divide-by-2 external clock when used in either baud-rate generator or clock output mode.

Capture/reload select. This bit determines whether the capture or reload function is used for timer 2. If
either RCLK or TCLK is set, timer 2 functions in an autoreload mode following each overflow. Setting this

bit to 1 causes a timer 2 capture to occur when a falling edge is detected on T2EX if EXEN2 is 1.

Clearing this bit to 0 causes an autoreload to occur when timer 2 overflow, or a falling edge, is detect-

ed on T2EX if EXEN2 is 1.