9400200990 Rev B

DGC-2020 Modbus

Communication

B-17

Holding

Register

Parameter Range

Read/Write

Supported

Data

Format

Units

40379

Miscellaneous condition DTC
status for specific engine
parameters from J1939
(DTC = diagnostic trouble code). In
this case, miscel-laneous refers to
DTCs other than what can be
represented by the bits in Modbus
register 40378.

0-65535 R

b0: fuel delivery pressure DTC;
b1: oil level DTC;
b2: oil filter diff. pressure DTC;
b3: oil pressure DTC;
b4: crankcase pressure DTC;
b5: coolant pressure DTC;
b6: coolant temperature DTC;
b7: coolant level DTC;
b8: oil temperature DTC;
b9: engine speed DTC;
b10-b15: NOT USED

40380-81 FUTURE

USE

40382

MDEC module type

1-4

R W

1 = module type 201
2 = module type 302
3 = module type 303
4 = module type 304

40383

MDEC speed demand switch

0-7

R W

0 = ANALOG_CAN
1 = UP_DN_ECU
2 = UP_DN_CAN
3 = ANALOG_ECU
5 = FREQUENCY
7 = NO_CAN_DEMAND

40384

MDEC RPM request for engine

1400-2000

R W

40385

Volvo Accelerator Pedal Position
(Trim)

0-100 R

W

0 = Rated speed – 120rpm;
50 = Rated speed;
100 = Rated speed + 120rpm.

40386

Volvo Engine RPM Select

0-1

R W

0 = Primary,
1 = Secondary.

40387

J1939 source address for this unit

0-253

R W

40388

J1939 Engine Start/Stop
Configuration

0-65535 R

W

0 = Not configured;
1 = Volvo Penta EDC3
2 = MTU MDEC

40389

Modem Dialout Conditions
Configuration Part 2 of 2

R

W

40390

Modem Dialout Conditions
Configuration Part 2 of 2

R

W

40391

Coolant Level Alarm Enable

True or False

R W

40392

Coolant Level Alarm Threshold

1 to 99

R W

%

40393

Coolant Level Pre-alarm Enable

True or False

R W

40394

Coolant Level Pre-alarm Threshold

1 to 99

R W

%

40395

ECU Settling Time

0-65535 R

W

milliseconds

40396

ECU Pulse Cycle Time - The
amount of time unit is to wait in
OFF between Pulse Cycles.

0-65535 R

W

minutes

40397

ECU Disconnect Time - The
amount of time ECU is kept
powered off.

0-65535 R

W

seconds

40398

ECU Connect Time - The amount
of time ECU is powered when
connecting (unit tries to run). Also
used for the Pulse duration time.

0-65535 R

W

seconds

40399-420 FUTURE

USE

J1939 DATA

40421

Accelerator Pedal Position

0 to 100%

R

0.4%/bit gain, 0% offset

40422

Percent Load At Current Speed

0 to 125%

R

1%/bit gain, 0% offset

40423

Actual Engine Percent Torque

0 to 125%

R

1%/bit gain, -125% offset

40424

Engine Speed

0 to 8031.875

R

RPM (0.125rpm/bit gain)

40425

Injection Control Pressure2

R