Winco DGC-2020 User Manual

Page 177

Advertising
background image

9400200990 Rev B

DGC-2020 Modbus

Communication

B-19

Holding

Register

Parameter Range

Read/Write

Supported

Data

Format

Units

40460

Torque At Idle Point3

0 to 125%

R

1%/bit gain, -125% offset

40461

Speed At Idle Point4

0 to 8031.875
rpm

R

0.125 rpm/bit, 0 rpm offset

40462

Torque At Idle Point4

0 to 125%

R

1%/bit gain, -125% offset

40463

Speed At Idle Point5

0 to 8031.875
rpm

R

0.125 rpm/bit, 0 rpm offset

40464

Torque At Idle Point5

0 to 125%

R

1%/bit gain, -125% offset

40465

Speed At High Idle Point6

0 to 8031.875
rpm

R

0.125 rpm/bit, 0 rpm offset

40466

Gain Of End speed governor

0 to 50.2 %/rpm

R

0.0007813 % engine reference
torque/rpm per bit gain (normalized),
0 %/rpm per bit offset

40467

Reference Engine Torque

0 to 64 255 Nm

R

1 Nm/bit gain, 0 Nm offset

40468 Override

Speed

Point7

0 to 8031.875
rpm

R

0.125 rpm/bit, 0 rpm offset

40469

Override Time Limit

0 s to 25 s

R

0.1 s/bit gain, 0 s offset

40470

Speed Lower Limit

0 to 2500 rpm

R

10 rpm/bit gain, 0 rpm offset

40471

Speed Upper Limit

0 to 2500 rpm

R

10 rpm/bit gain, 0 rpm offset

40472

Torque Lower Limit

0 to 125%

R

1%/bit gain, -125% offset

40473

Torque Upper Limit

0 to 125%

R

1%/bit gain, -125% offset

40474 Crankcase

Pressure

-250 to +251.99
kPa

R

0.0078125 kPa/bit gain,
-250 kPa offset

40475

Oil Filter Diff. Pressure

0 to 125 kPa

R

0.5 kPa/bit gain, 0 offset

40476

Fuel Filter Diff. Pressure

0 to 500 kPa

R

2 kPa/bit gain, 0 offset

40477-82 FUTURE

USE

40483

ECU Param. Status Group 1

R

bits 0-2: throttle position
bits 3-5: % load at present rpm
bits 6-8: actual % engine torque
bits 9-11: engine speed
bits 12-14: injection control pressure
Bit 15: NOT USED

3-Bit Status Flag Values:
000 for Valid Data
001 for No Comms
010 for Not Sent
011 for Not Supp
100 for Sender Error

40484

ECU Param. Status Group 2

R

bits 0-2: injector metering rail pressure
bits 3-5: engine run time
bits 6-8: trip fuel
bits 9-11: total fuel used
bits 12-14: coolant temperature
Bit 15: NOT USED

3-Bit Status Flag Values:
000 for Valid Data
001 for No Comms
010 for Not Sent
011 for Not Supp
100 for Sender Error

Advertising