Echelon IzoT Commissioning Tool User Manual

Page 52

Advertising
background image

network. This option is only available if you selected the Network
Attached
check box.

Skip Network Interface
Options Page

Skips the network interface page in the Network Wizard when you
create a new IzoT Commissioning Tool network.

Plug-Ins

Register Plug-Ins

Select this check box to register all enabled plug-ins when you create
a new IzoT Commissioning Tool network.

Skip Plug-ins Options
Page

Skips the plug-in registration page in the Network Wizard when you
create a new IzoT Commissioning Tool network.

User Logon

Skip Logon Options
Page

Skips the user logon page in the Network Wizard when you open an
IzoT Commissioning Tool network.

Management Mode

Select when changes made in your OpenLNS CT drawing are
transmitted to the physical devices on the network.

OnNet

Changes to the OpenLNS CT drawing are sent immediately to the
physical devices on the network. Select OnNet if you are
commissioning an engineered system or if you are working on any
phase of an ad-hoc system.

OffNet

Changes to the OpenLNS CT drawing are saved in the OpenLNS
network database, but are not propagated to physical devices until
IzoT Commissioning Tool is placed OnNet. Select OffNet if you are
designing an engineered system.

Once you have commissioned devices with IzoT Commissioning
Tool OnNet, you can make real-time changes to network variables
when IzoT Commissioning Tool is OffNet.

You can read and make changes to configuration properties while
IzoT Commissioning Tool is OffNet, but changes will not be
propagated until you set IzoT Commissioning Tool OnNet or you
manually propagate them (by right-clicking a device, pointing to
Commissioning, and selecting Propagate CP Values to Device on
the shortcut menu).

Skip Mode Options
Page

Skips the management mode page in the Network Wizard when you
create a new IzoT Commissioning Tool network.

Network Components

Drawing Template

Lists the templates available for new IzoT Commissioning Tool
networks. The template is an empty OpenLNS CT drawing that
specifies a default drawing background, styles, stencils, and other
IzoT Commissioning Tool settings. You can select from the
following three default IzoT Commissioning Tool templates that are
listed:

L

ON

W

ORKS

is the initial default template used for new

networks. It uses U.S. measurement units.

L

ON

D

EMO

is the template used to create a demonstration

network.

In

a demo network, you can only create a maximum

of five application devices.

L

ON

W

ORKS

Metric is a template that uses SI measurement

units for drawing pages.

36

Getting Started

Advertising