Opening an izot commissioning tool network design – Echelon IzoT Commissioning Tool User Manual

Page 71

Advertising
background image

and routers will be updated to match the new network database. Verify that IzoT Commissioning Tool
is not attached to the original network and then click Yes to proceed with your IzoT Commissioning
Tool set OnNet. Click No to return to the Management Mode page and set IzoT Commissioning Tool
OffNet.

Any devices you created and commissioned in your original network will have the same Neuron IDs in
the copied version. To avoid conflicts, make sure the domain IDs of the original and copied IzoT
Commissioning Tool network designs are unique, or make sure that the copied IzoT Commissioning
Tool network design is not attached to the physical network associated with the original version when
you are using it.

Monitoring will be disabled in the copy of the IzoT Commissioning Tool network. To enable
monitoring, right-click a clear space in the drawing page and click Enable Monitoring. See Chapter
6, Monitoring and Controlling Networks, for more information on how to monitor and control
application devices.

Opening an IzoT Commissioning Tool Network Design

To open an existing IzoT Commissioning Tool network, follow these steps:

1. Click Start on the taskbar, point to Programs, point to Echelon IzoT Commissioning Tool, and

then select IzoT Commissioning Tool. The IzoT Commissioning Tool Design Manager opens.

2. Choose the IzoT Commissioning Tool network you want to open. Under Existing Network,

select the desired drawing directory from the Drawing Directory list, and then select the network
you want to open from the Drawing Name list. For networks with multiple drawings files, you
can select any of the drawing files associated with the network.

3. To skip any or all of the pages in the Network Wizard when opening the existing network, clear

the Show all Options check box under the Existing Network box. The pages in the Network
Wizard will be skipped when you re-open the network provided that you previously selected the
check box at the bottom of the page (the Automatically Determine Server Location check box
for the Server Location page and the Skip This Prompt check box for all other pages). You can
also select the options to skip the pages in the Network Wizard in the OpenLNS CT drawing (to
do this, click Add-ins, click LonWorks Network, and click Network Properties). You cannot
skip the User Logon page if you have defined user profiles for the network (see User Profiles in
this chapter for more information).

4. Click Open Network.

IzoT Commissioning Tool User’s Guide

55

Advertising