AGI Security SYS-16HN44P User Manual

Page 302

Advertising
background image

290

Figure 5-103

Figure 5-104

Please refer to the following sheet for detailed information.

Parameter Function

Channel

Select speed dome connected channel.

PTZ Type

There are two options: local/remote.

Please select remote type if you are connecting to the network PTZ.

Protocol

Select the corresponding dome protocol such as PELCOD.

Address

Set corresponding dome address. Default value is 1. Please note

your setup here shall comply with your dome address; otherwise

you can not control the speed dome.

Baud
Rate

Select the dome baud rate. Default setup is 1115200.

Data Bit

The value ranges from 5 to 8. Default setup is 8. Please set according
to the speed dome dial switch setup.

Stop bit

The value ranges from 1 to 2. Default setup is 1. Please set according