Questions

Solutions

I can not connect to the

IPC

 Please make sure the IPC has booted up.
 IPC network connection is right and it is online
 IPC IP is in the blacklist.
 The device has connected to the too many IPC. It can not transmit

the video.

 Check the IPC port value and the time zone is the same as the

NVR.

 Make sure current network environment is stable.

After I set the NVR

resolution as 1080P, my

monitor can not display.

Shut down the device and then reboot. When you reboot, please press
the Fn button at the same time and then release after 5 seconds. You
can restore NVR resolution to the default setup.

My admin account has

been changed and I can

not log in.

Use telnet and then input the following command:

cd /mnt/mtd/Config/

rm -rf group

rm -rf password

Reboot the device to restore the default password.

After I login the Web , I

can not find the remote

interface to add the IPC.

Please clear the Web controls and load again.

There is IP and gateway, I

can access the internet

via the router. But I can

not access the internet

after I reboot the NVR.

Please use command PING to check you can connect to the gateway

or not. Use telnet to access and then use command “ifconfig –a” to
check device IP address. If you see the subnet mask and the gateway
has changed after the reboot. Please upgrade the applications and set
again.

I use the VGA montior.I

want to know if I use the

multple-window mode, I

see the video from the

main stream or the sub

stream?

 For 32-channel series product, the 9/16-window is using the sub

stream.

 For 4/8/16 series product, system is using the main stream no

matter you are in what display mode.

Daily Maintenance

 Please use the brush to clean the board, socket connector and the chassis regularly.

 The device shall be soundly earthed in case there is audio/video disturbance. Keep the device away

from the static voltage or induced voltage.

 Please unplug the power cable before you remove the audio/video signal cable, RS232 or RS485

cable.

 Do not connect the TV to the local video output port (VOUT).It may result in video output circuit.

 Always shut down the device properly. Please use the shutdown function in the menu, or you can

press the power button in the rear pane for at least three seconds to shut down the device.