Figure 2-45

Note
 There are two alarm input types: NO/NC.
 When connect the ground port of the alarm device to the NVR, you can use any of the GND ports

(

).

 Connect the NC port of the alarm device to the alarm input port (ALARM) of the NVR.
 When there is peripheral power supplying for the alarm device, please make sure it is earthed with

the NVR.

2.3.3 Alarm input and output port

 There is peripheral power supplying for the external alarm device.
 In case overload may result in NVR damage, please refer to the following relay specifications for

detailed information.

 A/B cable of the RS485 is for the A/B cable connection of the speed PTZ.

2.3.4 Alarm relay specifications

Model:

JRC-27F

Material of the

touch

Silver

Rating

(Resistance

Load)

Rated switch capacity

30VDC 2A, 125VAC 1A

Maximum switch power

125VA 160W

Maximum switch voltage

250VAC, 220VDC

Maximum switch currency

1A

Insulation

Between touches with same

polarity

1000VAC 1minute