Figure 2-24

The NVR42-8P series rear panel is shown as below. See Figure 2-25.

Figure 2-25

Please refer to the following sheet for detailed information.

Name

Function

Power

switch

/

Power on/off button.

Power input

socket

/

Input AC 100~240V.

For NVR42-8P series product only.

Power input port

Input DC 12V/5A.

For NVR42 series product only.

Power input port

Switch power port. Input DC 48//1.04A.

For NVR42-P series product only.

MIC IN

Audio input port

Bidirectional talk input port. It is to receive the analog

audio signal output from the devices such as

microphone, pickup.

MIC OUT

Audio output port Audio output port. It is to output the analog audio signal

to the devices such as the sound box.
 Bidirectional talk output.
 Audio output on 1-window video monitor.
 Audio output on 1-window video playback.

1~4

Alarm input port

1~4

 There are two types; NO (normal open)/NC

(normal close).

 When your alarm input device is using external

power, please make sure the device and the NVR

have the same ground.

GND

Alarm input ground port.

N1, N2

Alarm output port

1~2

 2 groups of alarm output ports. (Group 1:port

NO1~C1,Group 2:port NO2~C2).Output alarm

signal to the alarm device. Please make sure there

is power to the external alarm device.

 NO:Normal open alarm output port.
 C:Alarm output public end.

C1, C2

A

RS-485

communication

RS485_A port. It is the cable A. You can connect to the
control devices such as speed dome PTZ.

Advertising