Design Guide 1-27

Index:

“K” Factor........................................... 23
1000-1500 FPM .................................. 22
1750-2250 FPM .................................. 19
2000 FPM rule .................................... 18
275 BTUH/LINEAR FOOT................ 19
4 Relay Output Expansion Board.......... 4
400 BTUH/LINEAR FOOT................ 19
Air Motion .......................................... 19
Analog Output Board............................ 4
Auto-Zone Plus System

Diagram............................................. 2

Aux Heat ............................................. 26
AUX HEAT setpoint........................... 26
Auxiliary Heat..................................... 13
Auxiliary Heat Control Options.......... 25
Baseboard Heat ................................... 25
Box Heat ............................................. 26
Building Pressurization....................... 14
Bypass CFM........................................ 19
Bypass Damper

Defined.............................................. 7

Bypass Damper Sizing ........................ 19
Ceiling Diffuser .................................. 19
Central Unit

Sizing ........................................ 17, 18

CommLink IV

Described .......................................... 5

Constant Volume Controller

Defined.............................................. 8

Constant Volume Rooftop Units........... 4
Conventions .......................................... 1
Cooling

Partial Load Conditions .................. 10

Damper

Sizing .............................................. 19

Design Considerations ........................ 10
Design Guide ...................................... 15
Diffuser ............................................... 19
Downdrafts.......................................... 19
Duct Design ........................................ 18
Duct Static Pressure .............................. 7

Ducted Returns.................................... 11
East Exposures.................................... 17
Economizer ............................. 10, 12, 14
Ethernet Connection.............................. 6
Expansion Boards

Defined.............................................. 9

Exposures

East.................................................. 17
North ............................................... 17
South ............................................... 17
West ................................................ 17

Fan Powered Boxes............................. 25
First Stage Heat................................... 25
Heating

Sizing .............................................. 18

Heating - Partial Load Conditions ...... 13
Heating Difficulties............................. 13
Heating Requirements......................... 25
High Duct Static.................................. 12
HVAC Unit Installation

Diagram............................................. 3

Incorrect Zoning

Diagram........................................... 16

Installation

HVAC Unit ....................................... 3

Internet .................................................. 6
IP Module Kit

Defined.............................................. 6

Linear Slot Diffusers........................... 19
Load Program...................................... 22
Low Ambient Temperature Lockout... 10
Low Supply Air Temperatures............ 11
Low Temp Lockouts ........................... 10
Modulating Box Heat.......................... 26
Modulating Chilled Water Valve.......... 4
Modulating Hot Water Valve................ 4
Noise Levels........................................ 11
Noise Problems ................................... 18
North Exposures.................................. 17
Optimal Start......................................... 4
Override Conditions............................ 13

Advertising