Troubleshooting sFlow configuration

The remote sFlow collector cannot receive sFlow packets

Symptom

The remote sFlow collector cannot receive sFlow packets.

Analysis

The sFlow collector is not specified.

sFlow is not configured on the interface.

The IP address of the sFlow collector specified on the sFlow agent is different from that of the remote
sFlow collector.

No IP address is configured for the Layer 3 interface on the device. Or the IP address is configured,
but the UDP packets that have the IP address as the source cannot reach the sFlow collector.

The physical link between the device and the sFlow collector fails.

Solution

1.

Check that sFlow is correctly configured by using display sflow.

2.

Check that a correct IP address is configured for the device to communicate with the sFlow
collector.

3.

Check the physical link between the device and the sFlow collector.