Troubleshooting PoE

Failure to set the priority of a PoE interface to critical

Analysis

The guaranteed remaining power of the PSE is lower than the maximum power of the PoE interface.

The priority of the PoE interface is already set.

Solution

In the first case, either increase the maximum PSE power or reduce the maximum power of the PoE
interface if the guaranteed remaining power of the PSE cannot be modified.

In the second case, remove the priority that is already configured.

Failure to apply a PoE profile to a PoE interface

Analysis

Some configurations in the PoE profile are already configured.

Some configurations in the PoE profile do not meet the configuration requirements of the PoE
interface.

Another PoE profile is already applied to the PoE interface.

Solution

In the first case, remove the original configurations.

In the second case, modify the configurations in the PoE profile.

In the third case, remove the application of the undesired PoE profile from the PoE interface.