Step Command

Remarks

Optional.

410.

Configure PoE interface
power supply mode.

poe mode signal

By default, power is supplied to

PDs over signal wires (data pairs).

Optional.

411.

Configure a description for
the PD connected to the PoE

interface.

By default, no description for the

PD connected to the PoE interface
is available.

poe pd-description text

Detecting PDs

Enabling the PSE to detect nonstandard PDs

There are standard PDs and nonstandard PDs. Usually, the PSE can detect only standard PDs and supply

power to them. The PSE can detect nonstandard PDs and supply power to them only if you enable the PSE

to detect nonstandard PDs.
To enable the PSE to detect nonstandard PDs:

Step Command

Remarks

412.

Enter system view.

system-view

N/A

413.

Enable the PSE to detect
nonstandard PDs.

By default, the PSE can detect
only standard PDs.

poe legacy enable pse pse-id

Configuring a PD disconnection detection mode

CAUTION:

If you change the PD disconnection detection mode while the device is running, the connected PDs are

powered off.

To detect the PD connection with a PSE, PoE provides two detection modes: AC detection and DC

detection. The AC detection mode uses less energy than the DC detection mode.
To configure a PD disconnection detection mode:

Step Command

Remarks

414.

Enter system view.

system-view

N/A

Optional.

415.

Configure a PD disconnection

detection mode.

poe disconnect { ac | dc }

The default is AC.