Router C operates in broadcast server mode and sends broadcast messages from Ethernet 1/1.

Router B and Router A operate in broadcast client mode and receive broadcast messages through
their respective Ethernet 1/1.

Figure 19 Network diagram

Eth1/1

3.0.1.31/24

Eth1/1

3.0.1.32/24

Router A

Router C

Router B

Eth1/1
3.0.1.30/24

Configuration procedure

1.

Set the IP address for each interface as shown in

Figure 19

. (Details not shown.)

2.

Configure Router C:
# Specify the local clock as the reference source, with the stratum level 2.

<RouterC> system-view

[RouterC] ntp-service refclock-master 2

# Configure Router C to operate in broadcast server mode and send broadcast messages through

Ethernet 1/1.

[RouterC] interface ethernet 1/1

[RouterC-Ethernet1/1] ntp-service broadcast-server

3.

Configure Router A:
# Configure Router A to operate in broadcast client mode and receive broadcast messages on
Ethernet 1/1.

<RouterA> system-view

[RouterA] interface ethernet 1/1

[RouterA-Ethernet1/1] ntp-service broadcast-client

4.

Configure Router B:
# Configure Router B to operate in broadcast client mode and receive broadcast messages on
Ethernet 1/1.

<RouterB> system-view

[RouterB] interface ethernet 1/1

[RouterB-Ethernet1/1] ntp-service broadcast-client

Router A and Router B get synchronized upon receiving a broadcast message from Router C.
# Take Router A as an example. Display the NTP status of Router A after clock synchronization.

[RouterA-Ethernet1/1] display ntp-service status

Clock status: synchronized

Clock stratum: 3

Reference clock ID: 3.0.1.31