Configuration procedure

Before you perform the following configuration, be sure you have completed MPLS VPN-related

configurations and make sure of the reachability between CE 1 and PE 1, between PE 1 and PE 2, and
between PE 2 and CE 3. For information about configuring MPLS VPN, see MPLS Configuration Guide.

Figure 23

. (Details not shown.)

1.

Set the IP address for each interface as shown in

2.

Configure CE 1:
# Specify the local clock as the reference source, with the stratum level 1.

<CE1> system-view

[CE1] ntp-service refclock-master 1

3.

Configure PE 2:
# Specify CE 1 as the NTP server for VPN 1.

<PE2> system-view

[PE2] ntp-service unicast-server 10.1.1.1

# Display the NTP session information and status information on PE 2 a certain period of time later.
The information should show that PE 2 has been synchronized to CE 1, with the stratum level 2.

[PE2] display ntp-service status

Clock status: synchronized

Clock stratum: 2

Reference clock ID: 10.1.1.1

Nominal frequency: 63.9100 Hz

Actual frequency: 63.9100 Hz

Clock precision: 2^7

Clock offset: 0.0000 ms

Root delay: 47.00 ms

Root dispersion: 0.18 ms

Peer dispersion: 34.29 ms

Reference time: 02:36:23.119 UTC Jan 1 2001(BDFA6BA7.1E76C8B4)

[PE2] display ntp-service sessions

source reference stra reach poll now offset delay disper

**************************************************************************

[12345]10.1.1.1 LOCL 1 7 64 15 0.0 47.0 7.8

note: 1 source(master),2 source(peer),3 selected,4 candidate,5 configured

Total associations : 1

[PE2] display ntp-service trace

server 127.0.0.1,stratum 2, offset -0.013500, synch distance 0.03154

server 10.1.1.1,stratum 1, offset -0.506500, synch distance 0.03429

refid 127.127.1.0

Configuration example for MPLS VPN time synchronization in

symmetric peers mode

Network requirements

As shown in

Figure 23

, two VPNs are present on PE 1 and PE 2: VPN 1 and VPN 2. CE 1 and CE 3

belong to VPN 1. To synchronize the time between PE 1 and CE 1 in VPN 1, configure CE 1’s local clock

54

Advertising