You can successfully create a history control entry, even if the specified bucket size exceeds the

history table size supported by the device. However, the effective bucket size will be the actual value
supported by the device.

To configure the RMON history statistics function:

Step Command

34.

Enter system view.

system-view

35.

Enter Ethernet interface view.

interface interface-type interface-number

36.

Create an entry in the RMON history

control table.

rmon history entry-number buckets number interval
sampling-interval [ owner text ]

Configuring the RMON alarm function

Follow these guidelines when you configure the RMON alarm function:

To send traps to the NMS when an alarm is triggered, configure the SNMP agent as described in
"Configuring SNMP" before configuring the RMON alarm function.

If the alarm variable is a MIB variable defined in the history group or the Ethernet statistics group,
make sure the RMON Ethernet statistics function or the RMON history statistics function is

configured on the monitored Ethernet interface. Otherwise, even if you can create the alarm entry,

no alarm event can be triggered.

You cannot create a new event, alarm, or private alarm entry that has the same set of parameters
as an existing entry. For parameters to be compared for duplication, see

Table 2

.

After the maximum number of entries is reached, no new entry can be created. For the table entry

limits, see

Table 2

.

To configure the RMON alarm function:

Step Command

Remarks

37.

Enter system view.

system-view

N/A

rmon event entry-number [ description string ] { log |
log-trap log-trapcommunity | none | trap
trap
-community } [ owner text ]

38.

Create an event entry in

the event table.

N/A

Create an entry in the alarm table:

rmon alarm entry-number alarm-variable

sampling-interval { absolute | delta }
rising-threshold threshold-value1 event-entry1

falling-threshold threshold-value2 event-entry2

[ owner text ]

39.

Create an entry in the

alarm table or private
alarm table.

Use at least one
command.

Create an entry in the private alarm table:

rmon prialarm entry-number prialarm-formula

prialarm-des sampling-interval { absolute |
changeratio | delta } rising-threshold

threshold-value1 event-entry1 falling-threshold

threshold-value2 event-entry2 entrytype { forever |
cycle cycle-period } [ owner text ]