8.0 Using a BMK

94

© 2012 Magnum Energy, Inc.

8.0 Using a ME-BMK

This section discusses how to set up and monitor Magnum’s Battery Monitor Kit

(ME-BMK) using the ME-ARC remote. It also covers other BMK menu options

that are available using this remote. Use the mini-index below to direct you to

the appropriate section.
8.1 BMK Setup

p. 94

8.2 Monitoring the BMK

p. 95

8.3 BMK Menu Maps

p. 98

8.1 Setting Up the BMK

Use the ARC remote’s SETUP button to establish the charge effi ciency and amp-

hour size settings for your battery monitor (ME-BMK).
SETUP: 05 BMK Setup
This section provides information about charge effi ciency and how to manually

access/adjust this setting and the amp-hour setting.

05A Charge Eff This menu enables you to manually access and adjust

your battery’s charge effi ciency. The charge effi ciency setting allows the

battery monitor to calculate the battery’s charge effi ciency. Normally, the

ME-BMK battery monitor automatically calculates the battery’s effi ciency.
Default setting: Auto
Range: Auto, 50%-97%

Info: The factory default Auto setting allows the charging effi ciency

to be automatically calculated. In most circumstances, the Auto

setting will determine the best charge effi ciency.
CAUTION: If you do not know your battery’s charging effi ciency,

leave it at the factory default setting. If the setting is manually set

but incorrect, the state-of-charge (SOC) information will become

more inaccurate with every charge.

What is charge effi ciency? When a certain amount of energy is removed or

discharged from the battery, this removed energy will need to be returned to

keep the batteries at a 100% state-of-charge. As batteries are being charged,

they lose energy—either in the form of heat, or while gassing. This loss of energy

while charging means the battery will not be fully charged if you only return

the current that was removed. To compensate for the battery’s ineffi ciencies

while charging, a charge effi ciency setting is provided. The charge effi ciency

setting compensates the AH I/O (Amp-Hours In/Out) reading by ensuring the

AHs returned to the battery are greater than the AHs removed.
For example, if your AH I/O display reads 000 and you begin powering a

25-amp load for two hours, the display will show -050. This indicates that you

have discharged 50 AHs (2 x 25) from the battery. If the charge effi ciency

setting is set to 95%, then as you begin charging and return 50 AHs, the

AH I/O reading will be less than zero, indicating that the AHs removed have

not been fully returned. The 95% charge effi ciency setting requires 52.5 AHs

(50/95) to be returned before the AH I/O returns to 0.
How do I access the charge effi ciency setting? Press the ARC’s SETUP

button, rotate the SELECT knob to the 05 BMK Setup menu, and then press the

SELECT knob again to access the 05A Charge Eff menu item (see Figure 8-1).