7.0 Using an AGS Module

78

© 2012 Magnum Energy, Inc.

• AC

In

• Gen

Cooldown

• Gen

Warm-up

• Manual

Run

• No

Comm

• Off
• Quiet

Time

• Ready

• Start

Amp

• Start

Exercise

• Start

SOC

• Start

Temp

• Start

Test

• Start

Time

• Start

Topoff

• Start

VDC

Gen Run Fault

• Fault

Amp

• Fault

Exercise

• Fault

SOC

• Fault

Temp

• Fault

Test

• Fault

Time

• Fault

Topoff

• Fault

VDC

• Fault

MaxRn

ON: The ON selection manually starts the generator by sending a “start”

command from the AGS module. Once the generator is started, it must be

manually stopped, either from an external stop switch or by selecting OFF

from the 03 Gen Control menu, which sends a “stop” command from the

AGS module.

Info: When “ON” is selected, the Magnum inverter will not attempt to

accept the generator AC voltage until the warm-up period is satisfi ed.

Info: You can manually start the generator and have it automati-

cally stop by selecting ON from the 03 Gen Control menu, and then

changing the selection to AUTO to automatically stop the genera-

tor. When AUTO is selected after the generator has been manually

started, it displays the AGS status as “Start VDC” and uses the stop

setting in the SETUP button’s 04A Gen Run VDC menu (even if not

active) or the 04F Max Gen Run Time menu, whichever occurs fi rst.

This is useful if you want to make sure the generator starts before

you leave; the Max Gen Run Time setting ensures the generator

does not run longer than required.

AUTO: This selection uses the settings from the SETUP button’s 04 AGS Setup

menus to automatically start and stop the generator. Refer to the 04 AGS Setup

menus in Section 7.1 to set the start and stop parameters for the generator.

7.3.2 Monitoring the AGS

The ME-ARC remote’s METER and TECH buttons have additional menus that

are helpful for the proper operation and monitoring of your AGS system.

7.3.2.1 ME-ARC Remote’s AGS METER Button

Press the ME-ARC remote’s METER button, rotate the SELECT knob to the 03

AGS Meter menu, and then press the SELECT knob to access the AGS Meter

read-only menus. Rotate the SELECT knob to view the various AGS meters.
METER: 03A AGS Status Menu
This read-only menu displays the AGS’s current status. There are 26 differ-

ent status messages that can display to identify what state the AGS is cur-

rently in—only one displays at any one time (refer also to Figure 7-2).
Available statuses are (see Tables 7-2 thru 7-4 for information on each):

Info: This menu is important when determining if the AGS is work-

ing correctly, or for troubleshooting an AGS installation. For any

fault mode displayed in the status menu, refer to Section 7.7.3 in

this manual.