3.0 Setup

Set Absorb Done (SOC) – This setting can be used if a battery moni-

tor kit is installed, and you want to use the SOC (State of Charge) of

the battery bank to determine when the batteries are fully charged. The

SOC is the best way to determine when the batteries are fully charged.

The SOC also is helpful because any DC loads or other charge sources

connected to the battery bank will not affect the SOC reading, and the

batteries will always receive a full charge.
Default setting: Absorb Done SOC = 100%
Range: 50-100%

Info: A ME-BMK is required in order to use the Absorb Done SOC

setting. If the Absorb Done SOC setting is selected and there is no

ME-BMK installed in the system, or if a valid SOC number is not

displayed under the METER/04 BMK Meters/04B SOC menu (i.e.,

Think’n, No Comm, Pwr-up Fault are not valid SOC numbers), then

the charger will immediately go to the Float Charge stage once the

Bulk Charge stage is fi nished.
Info: If the Absorb Done SOC setting is used when charging from

a generator source, then it is recommended that a setting of less

than 100% be used (usually around 90% is acceptable). This lower

setting is used because running the generator past the 90% set-

ting is sometimes considered an ineffi cient use of fuel. If a setting

lower than 100% is used, then at least once a week the batteries

should be charged to 100%, to make sure damage is not done to

the batteries by not bringing them to a full charge state.

• 03F Max Charge Time The Max Charge Time setting is a safety fea-

ture that ensures abnormal conditions will not cause the charger to hold

batteries at a high voltage for a prolonged period of time. This menu sets

a maximum time the charger is allowed to operate in either the Bulk or

Absorption Charge mode. If the charger reaches the maximum charge

time setting, it will transition to the fi nal charge stage as set in the SETUP

button’s 03G Final Charge Stage.
Default setting: Max Charge Time = 12.0 Hrs
Range: 0.0-25.5 Hrs

Where should I set my Max Charge Time? In order to ensure a complete

charge cycle is accomplished, adjust the Max Charge Time setting to a time

period that will normally be longer than the settings in the following SETUP

menu items: 03E Absorb Done Time, 03E Absorb Done Amps, and 03E Absorb

Done SOC. The Max Charge Time setting has priority over these menus and

will stop the charge cycle once that setting is satisfi ed.
Example: The Max Charge Time setting is six hours, but the Absorb Done

Time setting is eight hours. The charge cycle will stop after six hours as per

the Max Charge Time setting, and not fi nish the Absorb Done Time setting

of eight hours.

Advertising