2.0 Installation

2.4.2 Surface Mount Installation Procedure

To surface mount, you must use the supplied bezel (Figure 2-4).

Info: The bezel has tabs at the bottom and side that are made with

thinner material (Figure 2-4). They can be cut or broken out to allow

the cable to be routed downward or to the side (Figure 2-6).

1. Using the bezel as a template, mark on the wall the location of the four

bezel mounting screws, and then drill pilot holes for the #8-32 screws.

2. Cut/break the appropriate tab for the planned route of the remote cable.
3. Pull the cable thru the bezel and place the bezel side with the removed

tab over the cable against the wall.

4. Position the bezel over the drilled mounting holes, and then screw the

bezel to the wall using the supplied Phillips screws (Figure 2-6).

5. Route the other end of the cable to the inverter/charger, and then plug

it into the inverter’s RJ11 REMOTE port (blue label)— inverter has DC

power, but is OFF. See Figure 2-2.

6. Take the other end of the cable and while plugging it into the back of

the ME-ARC, view the remote’s display to ensure the Power-up Self Test

initiates (see Section 2.5).

7. If the self test is successful, secure the ME-ARC to the bezel using four

of the supplied Phillips screws. If the self test is unsuccessful, refer to

the Section 6.0 “Troubleshooting”.

Figure 2-6, Surface Mounting the ME-ARC using the Bezel