5 tech button and menus, Tech: 01 temperatures, 0 setup – Magnum Energy ME-ARC Remote User Manual

Page 44

Advertising
background image

38

© 2012 Magnum Energy, Inc.

3.0 Setup

Rotary

SELECT

Knob

LCD

Display

TECH Button

Press to

select TECH

menu

Press

TECH

Rotate to

desired

selection:

01 Temperatures

Press SELECT

Top line shows

current TECH menu

heading

Bottom line shows

current TECH menu

selection/current setting

To select the next

TECH menu

01 Temperatures

Press SELECT

...

...

04 Fault History

Press SELECT

06 Ext Control

Press SELECT

07 Load Defaults

Press SELECT

Figure 3-7, TECH Button and Menus

3.3.5 TECH Button and Menus

The TECH menu button provides access to selections that are used to assist

service technicians in troubleshooting. It provides access to system informa-

tion along with a selection that allows all system settings to be returned to

their original factory default values.

TECH: 01 Temperatures
Displays the various temperatures measured throughout the system. Rotate

the SELECT knob to scroll through these temperature readings. The following

temperature displays are available:
• Batt

Sensor

– Displays the temperature of the inverter’s Battery Temp

Sensor (BTS) that is connected to the battery bank.

• Transformer

– Displays the temperature of the main power transformer

inside the inverter.

• Transistors

Displays the temperature of the inverter’s FETs (Field Effect

Transistors).

• AGS

– Displays the temperature of the AGS Temp Sensor that is plugged

into the REMOTE port on the ME-AGS-N module.

Info: The temperatures are displayed in Fahrenheit or Celsius, as

selected in the SETUP button’s 01E Temp Display menu.