3.0 Setup

3.2 Remote Feature to Inverter Compatibility

The ME-ARC has many settings and is designed to work with the advanced

features in your Magnum inverter—and/or other Magnum devices (i.e., ME-

AGS-N or ME-BMK). The ME-ARC communicates with your inverter to allow the

set up and enabling of these advanced features. However, when the ME-ARC

is released with new software, some of the features and functionality in the

remote may not be available in an inverter or networked accessory that has

an earlier software level. In this case, the advanced setting is not recognized

and will not function. Use the steps below to help you determine which ME-

ARC (Revision 3.0) menus/features are compatible with your inverter.
1. Go

to:

http://www.magnumenergy.com/Service/Compatibility.htm

to

determine your inverter’s compatibility level (L1, L2, L3 or L4).

2. Use Table 3-1 to determine which ME-ARC ‘features/settings’ you want

to use and what inverter compatibility level is required (see the “Model/

Level Required” column in Table 3-1).

3. If your inverter compatibility level is the same or greater than the level

required, your inverter can support the device setting/feature you want.

4. If your inverter does not have the required compatibility level for a fea-

ture/setting you want, contact Magnum Energy for a software upgrade.

Info: This compatibility matrix is available online to download/

print as a single page document and to enter user settings.

http://www.magnumenergy.com/Service/Compatibility.htm

.

Table 3-1, ME-ARC (Revision 3.0) Compatibility Matrix

Button

FEATURES/SETTINGS

Model/

Level

Required

Default

Setting

Main

Menu

Menu

Heading/Item

Selections/

Adjustments Range

CTRL

01 ACIn Control

Auto Connect

≥Level 1

Auto

Connect

VDC Connect, Time

Connect, AC-In Disabled

≥Level 3

[1]

SOC Connect

≥Level 3 [1][6]

02 CHG Control [5]

Multi-Stage, Force

Float, Restart Bulk

≥Level 4

Multi-

Stage

03 Gen Control

OFF, ON, AUTO

≥Level 1 [7]

OFF**

METER

01 DC

Meters

01A DC Volts

Read only display

≥Level 1

Read

Only

01B DC Amps

01C Charge

Time

02 AC

Meters

[5]

02A Output Volts

Read only display

≥Level 4

Read

Only

02B Output Hz

02C Load Amps

≥Level 4 [1, 3]

02D Input Amps

02E Inv/Chg

Amps

02F Input AC

(AC1)

02G Input AC2

MSH-RE Models