5 power-up self test, 0 installation 2.5 power-up self test, Magnum energy self test – Magnum Energy ME-ARC Remote User Manual

Page 13: Me-arc v 3.0 inv/chg v

Advertising
background image

© 2012 Magnum Energy, Inc.

7

2.0 Installation

2.5 Power-up Self Test

Info: All power to operate the remote control is provided by the

inverter/charger through the remote cable.

When the ME-ARC is first connected to an inverter, a power-up self test is

initialized. During the self test, the LCD automatically displays in sequence:
• “MAGNUM ENERGY Self Test”, then

“(C) 2010-2012, Connecting to...”, and then

“ME-ARC V 3.0, INV/CHG V #.#”

The remote’s LEDs also change with the screens (see Figure 2-7).

FAULT

PWR

CHG

INV

MAGNUM ENERGY

Self Test

FAULT

PWR

CHG

INV

(C)2010-2012

Connecting to..

FAULT

PWR

CHG

INV

ME-ARC V 3.0

INV/CHG V #.#

No LEDs light

PWR lights green

FAULT lights red

CHG lights green

INV lights green

CHG lights green

INV lights green

After the self test is finished the remote displays “Set Clock”.Use the ME-ARC’s

SELECT knob to set the correct time by selecting hour, minutes, and either

AM or PM (See Figure 2-8 below, and the Set Clock procedure on page 22).

Figure 2-7, Power-up Self Test Screens

Set Clock

AM-PM

=

12:00

A

Set Clock

Minute =

12:

12

A

Set Clock

Hour

= 12

:00A

Figure 2-8, Self Test Set Clock Screens