0 menu map – Magnum Energy ME-ARC Remote User Manual

Page 53

Advertising
background image

© 2012 Magnum Energy, Inc.

47

4.0 Menu Map

SETUP

continued….

Status/Fault...

03 Charger Setup

03D VAC Dropout

80 VAC / 75 VAC

Ranges: 60-100 VAC, UPS Mode (AC1 only)

Default: 80VAC (AC1); 75VAC (AC2)

Default: 100%

01 Temperatures

Press SELECT

TECH

01 Temperatures

Batt Sensor ##F

01 Temperatures

AGS ##F

01 Temperatures

Transformer ##F

01 Temperatures

Transistors ##F

S

TECH button menu map continues on next page

Read Only displays

02 Revisions

Press SELECT

02 Revisions

Inverter: 0.0

02 Revisions

Remote: 3.0

02 Revisions

AGS: 0.0

02 Revisions

BMK: 0.0

02 Revisions

Router: 0.0

S

Read Only displays

Range: 50-100%

Set VAC Dropout

AC1 = 60 VAC

Set VAC Dropout

AC1 = 80 VAC

Set VAC Dropout

UPS Mode

Set VAC Dropout

AC2 = 60 VAC

Set VAC Dropout

AC2 = 75 VAC

Set VAC Dropout

AC2 = 100 VAC

S

S

Status/Fault...

05 BMK Setup

Range: 0.0-25.5 Hrs

Status/Fault...

04 AGS Setup

03F Max Charge

Time = 12.0 Hrs

Set Max Charge

Time = 0.0 Hrs

Set Max Charge

Time = 12.0 Hrs

Set Max Charge

Time = 25.5 Hrs

Default: 12 Hrs

03G Final Charge

Stage = Multi

Set Final Charge

Stage = Multi

Set Final Charge

Stage = Float

Set Final Charge

Stage = Silent

Set DC Volts to

ReBulk = 12.0

Range: Multi, Float, Silent

Default: Multi

Range: 12.0-16.0 VDC (12v)

Default: 12.0 VDC

...

S

S

S

03E Absorb Done

Time = 2.0 Hrs

Set Absorb Done

Time

Set Absorb Done

Amps

Set Absorb Done

SOC

Range: Time, Amps, SOC

Set Absorb Done

Time = 2.0 Hrs

Set Absorb Done

Amps = 20 ADC

Set Absorb Done

SOC = 100%

Default: 20 ADC

Default: 2.0 Hrs

Range: 0.1-25.5 Hrs

Range: 0-150 ADC

S

S

S

S

Refer to AGS SETUP menu maps in

Section 7.0

Refer to BMK SETUP menu maps in

Section 8.0

...

* AC2 only displays on MSH4024RE models.

*

Export Ranges: 110-190 VAC, UPS Mode

Export Default: 150 VAC

Figure 4-4, SETUP/TECH Button Menu Maps