Tech: 07 load defaults, 0 setup – Magnum Energy ME-ARC Remote User Manual

Page 49

Advertising
background image

© 2012 Magnum Energy, Inc.

43

3.0 Setup

No Ext Control This menu indicates that the inverter/charger is not

being controlled externally.

#### – When this display shows a number or a series of numbers, it

indicates that one or more of the allowable functions of the inverter/

charger is currently being controlled externally. The number(s) displayed

can be used by Magnum technicians to determine what function(s) in the

inverter/charger is being controlled.

TECH: 07 Load Defaults

This menu restores factory defaults to all ME-ARC remote settings on

the inverter/charger and on any accessories that are network connected.

To restore, continually press the rotary SELECT knob until the ‘5.0 to 0.0

seconds’ countdown screen is fi nished and the screen displays “DEFAULTS

LOADED”. Refer to Table 3-4 for the remote’s default values for the inverter/

charger.

Info: Refer to Table 7-5 for AGS defaults, or to Table 8-1 for BMK

defaults when connected to an ME-ARC.

Info: If a PIN has been set and locked, it must be entered before

the Load Defaults menu can be used.

Table 3-4, Inverter/Charger Default Settings on ME-ARC

Menu Items

Default Settings

Search Watts

5 Watts

LowBatCutOut

10 VDC (12v)

20 VDC (24v)

40 VDC (48v)

AC In-Time

6:00A - 6:00P

AC In-VDC

11.0-14.1 VDC (12v)

22.0-28.2 VDC (24v)

44.0-56.4 VDC (48v)

Input Amps

30 Amps (AC1), 20 Amps (AC2)*

Battery Type

Flooded

Max Charge Rate

100%

VAC Dropout

80 VAC (AC1), 75 VAC (AC2)*

(Exports – 150 VAC)

Absorb Done

Time = 2 Hrs

Amps = 20 ADC

SOC = 100%

Max Charge Time

12.0 Hrs

Final Charge Stage

Multi

DC Volts to ReBulk

12.0 VDC

* AC2 settings available on MSH4024RE models only.