12.3 EFM OAM Example

Example:

CE and PE devices with point-to-

point link enable EFM OAM to monitor “the First Mile” link

performance. It will report the log information to network management system when occurring

fault event and use remote loopback function to detect the link in necessary instance

CE

PE

802.1ah OAMPDU

Ethernet

1/1

Ethernet

1/1

Typical OAM application topology

Configuration procedure: (Omitting SNMP and Log configuration in the following)

Configuration on CE:
CE(config)#interface ethernet1/1
CE (config-if-ethernet1/1)#ethernet-oam mode passive
CE (config-if-ethernet1/1)#ethernet-oam
CE (config-if-ethernet1/1)#ethernet-oam remote-loopback supported

Other parameters use the default configuration.

Configuration on PE:
PE(config)#interface ethernet 1/1
PE (config-if-ethernet1/1)#ethernet-oam

Other parameters use the default configuration.

Execute the following command when using remote loopback.
PE(config-if-ethernet1/1)#ethernet-oam remote-loopback

high

ethernet-oam errored-frame threshold high

{high-frames | none}

no ethernet-oam errored-frame threshold high

Configure the high threshold of errored

frame event, no command restores the

default value. (optional)

ethernet-oam errored-frame-seconds threshold

high {high-frame-seconds | none}

no ethernet-oam errored-frame-seconds

threshold high

Configure the high threshold of errored

frame seconds event, no command

restores the default value. (optional)