QTECH QSW-3400 Инструкция по настройке User Manual

Page 455

Advertising
background image

+7(495) 797-3311 www.qtech.ru
Москва, Новозаводская ул., 18, стр. 1

454

syslog similar applications on PC.

The log information is classified into eight classes by severity or emergency procedure. One

level per value and the higher the emergency level the log information has, the smaller its

value will be. For example, the level of critical is 2, and warning is 4, debugging is leveled at 7,

so the critical is higher than warnings which no doubt is high than debugging. The rule applied

in filtering the log information by severity level is that: only the log information with level equal

to or higher than the threshold will be outputted. So when the severity threshold is set to

debugging, all information will be outputted and if set to critical, only critical, alerts and

emergencies will be outputted.

Follow table summarized the log information severity level and brief description. Note: these

severity levels are in accordance with the standard UNIX/LINUX syslog.

Severity of the log information

Severity

Value

Description

emergencies

0

System is unusable

alerts

1

Action must be taken immediately

critical

2

Critical conditions

errors

3

Error conditions

warnings

4

Warning conditions

notifications

5

Normal but significant condition

informational

6

Informational messages

debugging

7

Debug-level messages

Right now the switch can generate information of following four levels

Restart the switch, mission abnormal are classified critical

Up/down interface, topology change, aggregate port state change of the interface are

notifications warnings

Outputted information from the CLI command is classified informational

Information from the debugging of CLI command is classified debugging

Log information can be automatically sent to corresponding channels with regard to respective

severity levels. Amongst the debugging information can only be sent to the monitor. Those with

the Informational level can only be sent to current monitor terminal, such as the information

from the Telnet terminal configuration command can only be transmitted to the Telnet terminal.

Warnings information can be sent to all terminal with also saved in the SDRAM log buffer zone.

And the critical information can be save both in SDRAM and the NVRAM (if exists) besides

sent to all terminals. To check the log save in SDRAM and the NVRAM, we can use the show

Advertising