14.4 DDM Troubleshooting

If problems occur when configuring DDM, please check whether the problem is caused by the

following reasons:

Ensure that the transceiver of the fiber module has been inserted fast on the port, or

else DDM configuration will not be shown.

Ensure that SNMP configuration is valid, or else the warning event cannot inform the

network management system.

Because only some boards and box switches support SFP with DDM or XFP with

DDM, ensure the used board and switch support the corresponding function.

When using show transceiver command or show transceiver detail command, it cost

much time due to the switch will check all ports, so it is recommended to query the

monitoring information of the transceiver on the specified port.

Ensure the threshold defined by the user is valid. When any threshold is error, the

transceiver will give an alarm according to the default setting automatically.