4 savi troubleshooting, Savi, Roubleshooting – QTECH QSW-3400 Инструкция по настройке User Manual

Page 395

Advertising
background image

+7(495) 797-3311 www.qtech.ru
Москва, Новозаводская ул., 18, стр. 1

394

connect with port Ethernet1/12 of Switch1 and port Ethernet1/13 of Switch2, and enable the

source address check function of SAVI. Ethernet1/1 and Ethernet1/2 are uplink ports of

Switch1 and Switch2 respectively, enable DHCP trust and ND trust functions. Aggregation

Switch3 enables DHCPv6 server function and route advertisement function.

Configuration steps of SAVI DHCP-SLAAC scene:
Switch1>enable
Switch1#config
Switch1(config)#savi enable
Switch1(config)#savi ipv6 dhcp-slaac enable
Switch1(config)#savi check binding probe mode
Switch1(config)#interface ethernet1/1
Switch1(config-if-ethernet1/1)#ipv6 dhcp snooping trust
Switch1(config-if-ethernet1/1)#ipv6 nd snooping trust
Switch1(config-if-ethernet1/1)#exit
Switch1(config)#interface ethernet1/12-20
Switch1(config-if-port-range)#savi ipv6 check source ip-address mac-
address
Switch1(config-if-port-range)#savi ipv6 binding num 4
Switch1(config-if-port-range)#exit
Switch1(config)#exit
Switch1#write

52.4 SAVI Troubleshooting

After ensure no problem about SAVI client hardware and cable, please check the status which

may exist and the propositional solutions in the following:

If IPv6 packets are filtered incorrectly after enable SAVI function, please ensure the

global SAVI function enabled. After that, enable the global function of the

corresponding SAVI scene according to the actual application scene and enable the

port authentication function.

If client can not correctly obtain IPv6 address assigned by DHCPv6 server after enable

SAVI function, please ensure DHCP port trust is configured by uplink port with

DHCPv6 server.

If node binding can not be set for the new user after enable SAVI function, please

check whether the direct-link port configures the max binding number, and whether the

binding number reaches to the max number. If the binding number exceeds the max

binding limit, it is recommended to configure the bigger binding limit.

Advertising